MIL-DTL-24784/14B(SH)
a. Column 1, Quantity. This column shall contain the quantity of each unit and accessories
supplied with the equipment.
b. Column 2, Item name or nomenclature. This column shall contain the official name (for
example, pump, winch) or nomenclature (name and designation) of each component, unit, or
accessory.
c. Column 3, PIN number, RIC number, or unit number. This column shall contain the PIN,
RIC, or unit number of each equipment unit or accessory.
d. Column 4, Overall dimensions. This column shall contain the crated (if available) and
uncrated height, width, and depth in inches (or inches and centimeters) of each unit or
accessory.
e. Column 5, Weight and volume. This column shall contain the crated (if available) and
uncrated weight and volume in cubic feet of each unit and accessory.
3.6.3.1.5 Equipment and publications required but not supplied. A tabular listing of all test
equipment and publications required but not supplied with the equipment or system shall be
included. Unless otherwise specified in the TMCR (see 6.2), NAVSEA ST000-AG-IDX-010
TMDE shall be used as a guide for the selection and application of test equipment required for
shipboard use. If a measurement requirement is established which cannot be satisfied by the
subcategory (SCAT) codes listed in this guide, or alternate test procedures cannot be developed
utilizing the listed SCAT request for assistance should be directed to:
Commander
Naval Sea Systems Command
Arlington, VA 22242-5160
ATTN: SEA 0415
The listing shall contain:
a. Column 1, SCAT code. When applicable, this column shall contain the four digit group of
numbers, which is included in NAVSEA ST000-AG-IDX-010 TMDE used to identify a
measurement requirement.
b. Column 2, Test equipment category. This column shall contain the item name of each item of
equipment required.
c. Column 3, Representative test equipment model number. This column shall contain the model
number of the standard or Substitute Standard General Purpose Electronic Test Equipment,
listed in NAVSEA ST000-AG-IDX-010 TMDE, which can be used to satisfy the
measurement parameters.
d. Column 4, Equipment test parameters. This column shall specify the range of test parameters
which must be satisfied by this test equipment item (it shall not define the ranges of the test
equipment model).
e. Column 5, Application. This column shall indicate the intended use of the test equipment (for
example, scheduled maintenance, troubleshooting, corrective maintenance, or installation).
3.6.3.1.6 Field and factory changes. Equipment changes (for example, field changes, factory
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business