MIL-DTL-24784/20B (SH)
d. Column 4, Equipment test parameters. This column shall specify the range of test parameters
which must be satisfied by this test equipment item (it shall not define the ranges of the test
equipment model).
e. Column 5, Application. This column shall indicate the intended use of the test equipment (for
example, scheduled maintenance, troubleshooting, corrective maintenance, or installation).
3.6.2.3.12 Field and factory changes. System and equipment changes (for example field
changes, factory changes, engineering changes or notices, modifications, and so forth) shall be
identified and included in separate tables. Field and factory changes shall be included as follows:
a. Column 1, Change number. This column shall list the change number for each field and
factory change considered and included in the preparation of the manual.
b. Column 2, Nomenclature. This column shall list the equipment nomenclature and
Government serial numbers of equipment affected by the change.
c. Column 3, Description. This column shall contain a brief statement identifying the change and
its purpose.
3.6.2.3.13 Description of technical manual. A brief description of the technical manual and an
introduction to the use of the data contained within shall be included.
3.6.3 Chapter 2, Scheduled maintenance. Chapter 2 shall contain all system schedule test
procedures, together with necessary explanations and illustrations. It is intended that the
engineering effort required to develop preventive maintenance data be expended only once and
that the data, where applicable be used both in this chapter and in Logistic Support Analysis
(LSA) or Maintenance Requirements Cards (MRC) where one or more of the latter three data
items are required by the contract (see 6.2). The preparation of this chapter of the manual should
therefore be delayed until completion of the LSA, or MRC; submissions of the manual draft copy
for review should be marked "TO BE SUPPLIED UPON COMPLETION OF LSA". When the
approved LSA, or MRC data is available, it shall be referenced in the manual. When included in
the manual, such LSA, or MRC data shall be integrated with other technical data required by this
specification to be in this chapter. Chapter 2 shall comprise the following:
a. Introduction.
b. Scheduled maintenance action index.
c. Scheduled test procedures.
When a separate depot-level manual is required (see 6.2), it shall include the information required
by MIL-DTL-24784 and MIL-DTL-24784/7, as applicable.
3.6.3.1 Introduction. The introduction shall be an explanation of the purpose, scope, and
arrangement of the scheduled maintenance material. When a preventive maintenance procedure is
critical to the operation of the system and the schedule for servicing is absolute (not
recommended), this information shall be conspicuously written as a CAUTION. The following
statement shall be included: