MIL-DTL-24784 / 21B (SH)
B
WASHER, FLAT, 0.750 in. ID, 0.312 in. OD, 0.066 in. thickness,
STEEL, ROUND., 0.750 in. ID, 0.312 in. OD, 0.066 in. thickness.
Items used fewer than five times need not be included in the list of attaching hardware providing
the item is completely identified in the parts list, following the part identification that is being
attached.
3.6.8.6 List of manufacturers. The list of manufacturers shall contain the names, addresses, and
CAGE number of all manufacturers supplying items for the equipment as referenced in the parts
list. The list shall be presented in numerical sequence by CAGE number. CAGE numbers shall be
in accordance with Cataloging Handbook H4/H8.
3.6.8.7 Parts location illustrations. Illustrations shall be included to provide positive and rapid
location of parts. Types of parts location illustrations include exploded views, when approved by
the Government, engineering drawings and sectional views, printed-circuit boards, as applicable
(see MIL-DTL-24784). (Suitable parts location illustrations located in other chapters of the
manual may be referenced).
3.6.8.8 Criteria for illustrations. Items shall be called out by reference designator. Standard
attaching hardware items (such as nuts, bolts, washers, screws) need not be called-out or
illustrated, except when they are referenced in a procedure. Exploded views shall be supplied
when required to support maintenance procedures in Chapter 6.
3.6.8.9 Exploded views. Exploded views for parts lists shall be prepared in accordance with
MIL-DTL-24784.
3.6.8.10 Line drawings, engineering drawings, and photographs. Line drawings shall be used in
lieu of photographs (see MIL-DTL-24784).
3.6.8.11 Printed circuit board. Printed-circuit board illustrations shall be prepared in accordance
with MIL-DTL-24784.
3.6.9 Chapter 8, Installation. Drawings and information concerning installation shall be
provided in this chapter (see 6.2). The following type of information shall be included: site
selection, or installation location guide lines (such as moisture precautions and maximum
temperature allowed as appropriate), special tools and materials requirements, unpacking, and
handling (if unusual procedures or precautions are required), preparation of foundations,
mechanical assembly procedures, mounting instructions, bolting diagrams, safety precautions,
grounding and bonding, clearances for access, ventilation, fluid cooling requirements, clearances
for motion under shock, and recommendations for reduction of electrical and EMI, and other
interface requirements, as applicable. In addition, this chapter shall contain tests and test
procedures required to demonstrate that the equipment after installation is capable of satisfying
operational requirements. Also, it shall include information relating to the electromagnetic
compatibility (EMC) measures taken in the original design or subsequently incorporated to
35