MIL-PRF-49503C (MI)
be green. For monochrome, the ATE and ICD receiver box shall contain a slash
pattern.
(b) Yellow. The ICD (see 6.5.2) box shall be yellow. For monochrome,
the ICD shall contain a cross-hatched pattern.
(c) White. Cables and cable connectors shall be white.
(d) Light blue. The UUT box shall be light blue. For monochrome, the UUT box
shall be outlined by a dashed line.
(e) Other colors. Other colors may be used as specified by the contracting
activity to accurately represent the actual hardware. If other colors are used, they
shall be used consistently throughout the TPS.
(f) Photographic, video, more realistic images, etc. As specified by the
contracting activity, photographic or other more realistic images as well as video
may e used if they are available.
(4) TEST STATUS SCREENS.
(a) Light blue. Item to be tested or test was bypassed shall be light blue.
For monochrome, the item shall be underlined.
(b) Yellow. A yellow status bar shall indicate that the test is in progress.
For monochrome, the status bar shall be dim.
(c) Green. When a test has passed, the status bar shall change from
yellow to green. For monochrome, the status box shall clear. If the bar is the last
bar on the screen, the screen shall remain on display for 3 to 10 seconds, after
which the TP shall advance to the next screen.
(d) Red. When a test has failed, the status bar shall change from yellow
to red (for monochrome from dim to reverse image) and remain red (reverse
image) as the test continues. If the bar is the last bar on the screen, or the test must
be interrupted as a result of the failure, then the screen shall remain on display for
3 to 10 seconds, after which the TP shall advance to the next screen.
c. Flash coding. Flash coding shall only be used when there is an urgent need to get
the operator's attention. The text shall have a flashing underline but the text shall not
flash. The rate of blinking shall be 1 to 2 flashes per second or as specified by the
contracting activity with a duty cycle of 50 percent. The operator shall be required to
acknowledge flash messages before the test can proceed.
d. Alternate coding such as upper case lettering, underlining, indentation, image