MIL-STD-334B(TM)
5.3.2.7 Location, pattern, color, graphical, and symbol coding. These techniques shall be used where appropriate to save time for the operator or the ATE. For example, if a UUT test path schematic is presented on the screen, the signal flow will be highlighted by color or pattern to aid the operator in tracing the signal flow.
5.3.2.8 Audio prompting. Audio codes may be used, as appropriate, to satisfy or supplement a requirement for video prompting. The choice of specific audio codes shall be consistent with the following principles:
a. The number of sound signals shall be limited to four (bell, beep, buzz, etc.). Steady signals that resemble hisses, static, or sporadic radio signals shall not be used.
b. Each sound shall have only one meaning. Once a particular sound signal code is established for a given operating situation, the same signal shall not be designated for some other display.
c. Audio levels shall be consistent throughout.
d. Audible signals shall be easily discernible from any ongoing input.
5.4 Display updating.
5.4.1 Display update rates. The update rates of system information being displayed in a tabular form shall be neither so slow nor so fast as to render the data unusable in the intended manner.
5.4.2 Visual integration. Graphic displays requiring operator visual integration of rapidly changing patterns shall be updated at a rate that shall be neither so slow nor so fast as to render the data unusable in the intended manner.
5.4.3 Display freeze. If possible, a display freeze option shall be provided to stop the program and allow close scrutiny of a selected frame.
5.4.4 Freeze feedback. An appropriate feedback label shall be provided to remind the operator when the display is in the freeze mode.
5.5 General information. General information shall be displayed before the start of testing and shall include all WARNINGS and CAUTIONS applicable during the test, as well as the following information:
a. A list of supporting programs, if applicable. b. ICD accessory equipment.
c. Related equipment publications.
d. Special operator requirements for UUT testing. e. Program date and revision identifier.
f. Identification numbers of compiler, run time system, and equipment tables required.
g. Serial number of the ATE system used.