MIL-DTL- 24784/11C(NAVY)
(12) Main steam:
(a)
List of pressure reducing stations including rating, number, location, equipments served.
(13) Auxiliary steam.
(14) Feed water, including main, booster recirculation control, and differential pressure control.
(15) Main condensate.
(16) Auxiliary condensate.
(17) Other auxiliary systems:
(a)
Lubricating oil.
(b) Fuel oil service.
(c)
Control air, machinery and piping system drainage (low pressure and high pressure).
e.
For the above systems and components in Part 1, general directions shall be included for operation, with
appropriate references to diagrams or other illustrations, for normal operation, split plant operation,
emergency operation, and standby operation. These procedures shall be summarized in a condensed
manner, for plant-wide operations for the following conditions:
(1) Standby.
(2) Warmup of main propulsion plant.
(3) Underway, cruising.
(4) Underway, full power.
(5) Secure, main propulsion plant.
(6) Moored at pier, using shore electric power and steam.
(7) Auxiliary steaming.
(8) Split plant operation
3.8.2.1.2 Part 2 - auxiliary machinery, piping, environmental pollution control, air-conditioning, ventilation and
heating systems. The systems and components in Part 2 shall be described in a manner to permit understanding of
their intended functions, operations, and limitations. A chapter shall be devoted to each piping system, each
independent auxiliary machinery plant, each air-conditioning, ventilation, and heating system and an overall chapter
pertaining to pumps. Wherever reference is made to a piping component, the component designation as specified in
the Ships Specification shall be included. Tables shall be included showing the time required to flood and drain
each damage control void and the time required to ballast and deballast each fuel and ballast tank or both, as
applicable to expedite fueling-at-sea. The ships liquid loading instruction shall be referenced, describing the manner
in which protection against fragment damage can be maintained as ship fuel and aviation fuel are pumped down.
The chapter on pumps shall be similar in format to the pump tables in Section 503 of the Ship Specification and
shall reference, in addition to the information contained in those tables, the applicable technical manual,
compartment name and number of space containing each pump, title of system in which pump is located, and the
applicable SIB chapter number of the system. The chapter shall be categorized into the following subsections, as
applicable: centrifugal, rotary, reciprocating, attached, and portable. The schedule for preparation of Volume 2,
Part 2 shall permit issue of approved preliminary chapters at least 30 calendar days prior to the operational check of
the associated system. Part 2 shall include, but is not restricted to the following:
a.
Auxiliary machinery plants:
(1) Auxiliary boilers.
(2) Refrigeration machinery.
(3) Air conditioning machinery.
(4) Steering system.
(5) Bow transfer system (where applicable).
(6) Fin stabilizer machinery (where applicable).
b.
Air-conditioning, ventilation, and heating systems - Section 512:
5