MIL-DTL-24784/12B(SH)
mechanical assembly procedures, mounting instructions, bolting diagrams, safety precautions,
grounding and bonding, clearances for access, ventilation, fluid cooling requirements, clearances
for motion under shock, and recommendations for reduction of electrical and EMI, and other
interface requirements, as applicable. In addition, this chapter shall contain tests and test
procedures required, to demonstrate that the equipment after installation is capable of satisfying
operational requirements. Also, it shall include information relating to the electromagnetic
compatibility (EMC) measures taken in the original design or subsequently incorporated to
maintain EMC integrity of the equipment at all times in its life cycle. The measures include, as a
minimum, shielding, filtering, grounding, bonding, and routing.
3.6.9.1 Installation drawings. Legible reproduction of appropriate installation control drawings,
shall consist of the following, as applicable.
a.
Drawing list.
b.
Block diagrams.
c.
Outline and installation drawing.
d.
Auxiliary cooling diagram.
e.
Auxiliary dry gas diagram.
f.
Cable running sheets.
g.
Summary list of installation material.
h.
RF transmission line diagram.
i.
Hydraulic fluid piping diagram.
3.6.9.2 Site or installation location information. Data shall contain information supplemental to
the installation drawings. If all site information is contained on the installation drawings,
reference shall be made to the applicable drawings by figure number.
3.6.9.3 Reference publications. Reference shall be made to military-issue general publications
required to complete the installation, when it is impractical to include such information.
3.6.9.4 Tools and materials required for installation. Include information supplemental to the
summary list of installation material. If no supplemental information is required, reference the
drawing by figure number.
3.6.9.5 Unpacking and repacking. Include information supplemental to the installation drawings
regarding unpacking and repacking. Include step-by-step procedures to prevent damage to the
equipment or injury to personnel. Supporting illustrations shall be provided to clarify procedures.
When packing for reshipment is required, step-by-step procedures for packing shall be included
and illustrated. When packing is simply the reverse of unpacking, this fact need only be stated.
Any special environmental conditions required for storage shall be provided. Instructions shall be
included for items in the following categories.
a. Depreservation procedures required at time of installation.
b. Represervation packaging required prior to repacking for storage or shipment.
c. Intricate mounting, blocking, or bracing.