MIL-DTL-24784/17B(SH)
monitoring of operational functions such as chemicals, data, temperatures, and so forth, required
for determining safe and reliable ship's operations. Such systems shall include but not be limited
to the following:
a.
Propulsion.
b.
Boiler.
c.
Electrical.
d.
Battery.
e.
Distilling.
f.
Fuel and fueling.
g.
Refrigeration.
h.
Environmental.
3.6.5.3.1 Waiver of requirement. When it is deemed necessary that the development of such a
form would be of no value to the Government for the equipment being covered, a waiver (with
justification and rationale) for standard log form requirements shall be requested at least 3 months
prior to submittal of the review draft copy.
3.6.5.3.2 Criteria. The "model" standardized log form shall serve as an operating log that shall
be a guide to all ships of all classes. It is not intended that this model will in any way inhibit an
individual ship from accommodating its specific needs through the addition or deletion of readings
as deemed necessary on a case basis. The basic criteria to be utilized in developing the model
shall be:
a. Analyzing the various parameters associated with monitoring the performance of the
equipment to ascertain those that provide trend determinant information.
b. Synthesizing the results of the above analysis to ensure that only "key" (that is, necessary)
parameters are included; the goal being to keep to an absolute minimum the total number of
log readings required in running the plant.
c. Arranging the order of monitoring on the appropriate log forms in such a manner that the log
keeper and the reviewing officer can quickly tell when problems, either short-term or long-
term in nature, are beginning to develop (that is, by function as opposed to order of physical
arrangement).
d. Duplicate readings shall be eliminated where feasible (that is, where the parameter is generally
associated with a single function and where duplicated readings are not normally compared
with one another).
3.6.5.3.3 Training summary. A training summary for use of the form shall also be included in
Chapter 4. It shall indicate how to use the chart and an explanation of the significance of the
monitoring points and readings.
3.6.5.3.4 Request for number. The contractor shall advise the Government of the requirement
for log forms. The Government shall arrange for a forms stock number, and printing and stocking
of the log form.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business