MIL-DTL-85383A(AS)
3.2.8.1 Repair of new/peculiar structure. Repair instructions and structurally significant or
functionally significant information for new or peculiar structure such as tapered skins, sandwich
material, honeycomb assemblies, reinforced plastics, and composite materials shall be included or
referenced as specified in MIL-DTL-81927 (see 3.1.4).
3.2.9 Structural group repair index. An index illustration shall be prepared for each major
structural group for which repair instructions are included in the manual. The index illustration
shall either begin on the page following the alphabetical index of the first WP containing specific
repair data for a structural group, or it shall be prepared as a WP immediately following the
alphabetical index WP of the volume containing the repair data. The following shall be included
on each index illustration:
a. A view of the structural group. Exploded views may be required to show hidden
components. Each component for which instructions are prepared shall be shown.
b. An index number assigned to each illustrated component.
c. A table. This table shall be on the first sheet or sheets of the illustration and shall be in the
following form:
ITEM
NOMENCLATURE
PART NUMBER
WP NUMBER
(1) Item column. This column shall show all assigned index numbers in numerical order.
(2) Nomenclature column. This column shall show the proper nomenclature by which
each item is identified throughout the manual. (Refer to "nomenclature consistency"
in MIL-DTL-81927.)
(3) Part number column. This column shall show the part number for each listed item.
(4) WP number column. This column shall show the number of the WP which contains
the damage evaluation instructions. Entries in this column shall have the following
form: 013 00/28.
3.2.10 Specific repair data WPs. Specific repairs are included to cover types of damage or
types of structure which cannot be adequately covered using typical repairs alone. Specific repair
WPs shall be prepared for each major structural group. The data in these WPs shall be presented
in the following sequence for each structural group:
a. Damage identification and evaluation data (see 3.2.3, 3.2.4).
b. Typical repair procedures when applicable (see 3.2.8).
c. Specific repair procedures (see 3.2.10.4).
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business