MIL-DTL-24784/14B(SH)
procedures or precautions are required), preparation of foundations, mechanical assembly
procedures, mounting instructions, bolting diagrams, safety precautions, grounding and bonding,
clearances for access, ventilation, fluid cooling requirements, clearances for motion under shock,
and recommendations for reduction of electrical and electromagnetic interference, and other
interface requirements, as applicable. In addition, this chapter shall contain tests and test
procedures required to demonstrate that the equipment after installation is capable of satisfying
operational requirements. Also, it shall include information relating to the electromagnetic
compatibility (EMC) measures taken in the original design or subsequently incorporated to
maintain EMC integrity of the equipment at all times in its life cycle. The measures include, as a
minimum shielding, filtering, grounding, bonding, and routing.
3.6.3.8.1 Installation drawings. When specified in the TMCR (see 6.2), reproduction of
appropriate installation control drawings shall consist of the following, as applicable:
a.
Drawing list.
b.
Block diagrams.
c.
Outline and installation drawing.
d.
Auxiliary cooling diagram.
e.
Auxiliary dry gas diagram.
f.
Cable running sheets.
g.
Summary list of installation material.
h.
RF transmission line diagram.
i.
Hydraulic fluid piping diagram.
3.6.3.8.2 Site or installation location information. When specified in the TMCR (see 6.2), data
shall contain information supplemental to the installation drawings. If all site information is
contained on the installation drawings, reference shall be made to the applicable drawings by
figure number.
3.6.3.8.3 Reference publications. When specified in the TMCR (see 6.2), reference shall be
made to military-issue general publications required to complete the installation, when it is
impractical to include such information.
3.6.3.8.4 Tools and materials required for installation. Include information supplemental to the
summary list of installation material. If no supplemental information is required, reference the
drawing by figure number.