MIL-DTL-24784/14B(SH)
OBSERVE
REFERENCE
STEP
1. Preliminary Procedure.
a. Position the following switches on
rear deck assembly 1A210A1 as
indicated.
Switch
POSITION
POWER
OFF
BATTLE SHORT OFF
STOW
BRAKES APPLY
b. Position POWER switch on console
1A220A20 (see figure 5-2) to OFF.
Covers Secured
c.
Check to ensure that all chassis or
subassemblies in the four
compartments of electronic rack
assembly, 1A70 are in the retracted
position and all covers are secured.
Director Clear
d. Remove all obstructions from the
rotational paths of the director main
antenna assembly.
2. Power off
a. At power control panel perform the
following.
Lighted
Schematic, figure 5-233
(1) Check convenience lamp
indicators.
e. At track meter panel, 1A340-02.
Relay diagram, figure
Extinguished
check COOLANT FAILURES lamp.
5-77, SH #(4B)
(Depress RESET
button if lamp is
lighted)
FIGURE 14-2. Maintenance turn-on procedure.