MIL-PRF-63045B (TM)
function from input to output, and shall show interconnection of the units. Signal levels, direction of flow,
wave forms, etc, shall be included as applicable.
3.3.8 Chapter 3 - Operating procedures.
3.3.8.1 Section I - Setup instructions. Site selection, unpacking, assembly, installation instructions, and
special tools and requirements for installation inspection and pre-energizing procedures shall be provided in
this section. Instructions shall also be given for establishing normal, neutral, zero, center, on-off, or any
required positions of each switch, control, or similar item before connecting to power when the equipment is
in shutdown status.
3.3.8.2 Section II - Controls and indicators. This section shall contain information which is needed by
the operator to properly identify, determine the function and use of, connect, operate, and protect the
equipment being used. Controls and indicators shall be supported by illustrations which identify and locate
all operator controls and indicators.
3.3.8.3 Section III - Turn-on and turn-off procedures. This section shall contain instructions to place the
equipment in operation, to operate the equipment in each mode of operation, to remove the equipment from
operation and put it in standby condition, and to remove it from operation and put it in shutdown status.
Instructions shall be provided for turning the equipment off during an emergency (fire, hazard to personnel,
loss of coolant, normal power, etc.), as applicable.
3.3.9 Chapter 4 - Maintenance requirements
3.3.9.1 Section I - Facilities, equipment, and material standards.
3.3.9.1.1 Facilities. The facilities required for maintenance of the test equipment, including special
factors such as environment, shall be listed.
3.3.9.1.2 Special tools and equipment. This portion shall contain the detailed description, instructions,
and illustrations for special tools and equipment which are necessary to perform maintenance on the test
equipment, including any items which must be locally fabricated. Specific dimensions and tolerances shall be
supplied for tools and fixtures.
3.3.9.1.3 Material standards. Unless otherwise specified by the contracting activity (see 6.2), this
portion shall state that parts and material used for replacement, repair, or modification shall meet all
applicable equipment drawings and specifications.
3.3.9.2 Section II - Preventive maintenance. This section shall contain a tabular listing of all periodic
checks, services, and safety precautions, including intervals, necessary to maintain the test equipment in an
operable state. References shall be made to applicable equipment lubrication orders (LO). If no applicable
LOs are published, lubrication instructions shall be included in this section, in tabular format, with illustrated
locations of lubrication points.